Sign In | Join Free | My burrillandco.com
Home > Electrical Safety Testing Equipment >

Vehicle Electrical Safety Testing Equipment Feedback Power Grid Simulator RS485

Sinuo Testing Equipment Co. , Limited
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap Vehicle Electrical Safety Testing Equipment Feedback Power Grid Simulator RS485 from wholesalers
     
    Buy cheap Vehicle Electrical Safety Testing Equipment Feedback Power Grid Simulator RS485 from wholesalers
    • Buy cheap Vehicle Electrical Safety Testing Equipment Feedback Power Grid Simulator RS485 from wholesalers
    • Buy cheap Vehicle Electrical Safety Testing Equipment Feedback Power Grid Simulator RS485 from wholesalers
    • Buy cheap Vehicle Electrical Safety Testing Equipment Feedback Power Grid Simulator RS485 from wholesalers
    • Buy cheap Vehicle Electrical Safety Testing Equipment Feedback Power Grid Simulator RS485 from wholesalers

    Vehicle Electrical Safety Testing Equipment Feedback Power Grid Simulator RS485

    Ask Lasest Price
    Brand Name : Sinuo
    Model Number : SNEBP
    Certification : Calibration Certificate (Cost Additional)
    Payment Terms : T/T
    Delivery Time : 45 days
    Supply Ability : 10 sets/month
    Price : Customized
    • Product Details
    • Company Profile

    Vehicle Electrical Safety Testing Equipment Feedback Power Grid Simulator RS485

    Electric Vehicle Feedback Power Grid Simulator

    Equipment Overview


    SNEBP series regenerative grid simulators are used in new energy industries such as charging piles, energy storage inverters, photovoltaic inverters, wind energy converters and other products for grid connection performance testing. The input end of the product adopts digital PWM rectification technology, and the output end adopts independent digital high-frequency inverter technology. It has full energy feedback to the grid, high input power factor, low grid pollution, high output waveform quality, fast dynamic response, and three-phase independent Adjustment and other advantages.


    Main Features

    1. With multiple output modes, powerful functions:

    (1)Three-phase standard mode: standard three-phase voltage output;

    (2)Three-phase unbalanced mode: the three-phase voltage is independently set, and the three-phase phase angle is adjustable from 0.0° to 359.9°;

    (3)Parallel single-phase mode: three-phase parallel connection into high-power single-phase output;


    2. The three-phase mode output adopts three-phase decoupling design, with comprehensive power grid abnormal simulation functions: grid distortion, grid fluctuation, three-phase unbalance, etc., and 2-40 harmonics can be superimposed in the harmonic mode;


    3. Equipped with four-quadrant operation function, realizing 100% energy feedback to the grid;

    Vehicle Electrical Safety Testing Equipment Feedback Power Grid Simulator RS485 Vehicle Electrical Safety Testing Equipment Feedback Power Grid Simulator RS485 Vehicle Electrical Safety Testing Equipment Feedback Power Grid Simulator RS485


    4. It meets the low (zero) voltage ride through test requirements specified by the NB/T32004-2013 standard, and the low (zero) voltage ride through performance is reliable, and it will not resonate with the load at low voltage.

    Vehicle Electrical Safety Testing Equipment Feedback Power Grid Simulator RS485 Vehicle Electrical Safety Testing Equipment Feedback Power Grid Simulator RS485


    5. Meet the high voltage ride through test requirements specified by the national standard;


    6. The dynamic response speed is fast, and the voltage mutation response time is within 20ms; the input power factor is high (≥095), and the input current distortion is low (<5%);


    7. With Auto-Lock function, the keyboard is automatically locked at regular intervals to prevent accidents or dangers caused by accidental contact.


    8. 8-inch color touch screen, all operations can be realized through the touch screen, the appearance is exquisite, the operation is convenient, and it is equipped with number keys, function keys, knobs, etc., and the operation is diversified;


    9. The measurement function is complete, capable of measuring voltage, current, peak current, frequency, active power, apparent power, power factor, voltage crest factor and other electrical energy parameters:


    10. With artificial intelligence monitoring (Al-Monitor) function, real-time monitoring of internal voltage, current, temperature and other parameters, abnormal conditions immediately alarm, and prompts for timely processing;


    11. With Black-Box function, it can automatically record operating parameters under abnormal conditions, which is convenient for later viewing and maintenance;


    12. The main components are international first-line well-known brands, reliable in quality, stable and durable


    13. The key indicators are designed with multiple margins, voltage stress, current stress, and heat generation have undergone rigorous type tests. The whole machine has high reliability and long life;


    14. The communication interface comes standard with RS232, RS485, GPIB, ETHERNET, analog control, etc. are selected.

    Vehicle Electrical Safety Testing Equipment Feedback Power Grid Simulator RS485


    Application

    Vehicle Electrical Safety Testing Equipment Feedback Power Grid Simulator RS485


    Function operation
    Ladder programming9999 steps
    Step programming100 steps, 999999 cycles
    Gradient programming100 steps, 999999 cycles
    Low (zero) voltage ride throughIt can simulate the standards of many countries in the world, and the minimum response time is ≤20ms
    High voltage ride throughIt can simulate the standards of many countries in the world, and the minimum response time is ≤20ms
    Wave formatSine wave or harmonic (2~40th harmonic superimposed)
    Real-time adjustment function

    1. In the normal mode start state, you can adjust the output voltage and frequency setting values through the number keys, increase and decrease keys, and knob, and update them immediately


    2. When the normal mode is activated, the output waveform format can be switched and updated immediately; 10 shortcut groups in the normal mode;

    Quick transfer10 shortcut groups in harmonic mode;
    Protective function
    Overload capacity

    105%<overload≤110% cut off the output after 15 seconds

    110%<overload≤200%

    200%<overload≤300% cut off output after 5 seconds cut off output after 2 seconds

    300%<overload, immediately cut off the output

    Protective deviceOver-current, overload, short-circuit protection, over-heat protection, output over-under-voltage, phase loss protection, bus over-under-voltage, output power contactor automatic trip protection
    Software protectionArtificial intelligence monitoring (al-monitor) function, black-box function, auto-lock key lock protection
    Remote interface
    Communication interfaceStandard: RS232, OPTIONAL: RS485, GPIB, ETHERNET
    Remote controlOptional: analog control port
    Input parameter
    Input phase numberThree-phase four-wire+PE
    Input voltage range380v 57v(l-l)
    Input frequency range45~65hz
    Input power factor

    >0.97 (input rated voltage, input 50%-100% rated current)

    >0.95 (input rated voltage, input 10%-50% rated current)

    Input current distortion<5% (under rated conditions)
    Working environment
    Operating temperature0-40℃
    Working humidity20-90% rh (non-condensing)
    Volume and weight
    Dimensions (w*h*d mm)1000*2000*8001800*2000*8002000*2000*1000
    Weight (kg)510600750105013501500165018502100

    Technical Parameters



    Product nameElectric Vehicle Feedback Power Grid
    Product number

    SNEBP

    015

    -3X

    SNEBP

    030

    -3X

    SNEBP

    045

    -3X

    SNEBP

    060

    -3X

    SNEBP

    090

    -3X

    SNEBP

    120

    -3X

    SNEBP

    150

    -3X

    SNEBP

    180

    -3X

    SNEBP

    240

    -3X

    Output/absorption capacity15kVA30kVA45kVA60kVA90kVA120kVA150kVA180kVA240kVA
    Basic functions
    Output functionWith comprehensive power grid simulation function
    Feedback abilityWith the function of 100% energy feedback to the grid
    Isolation functionBuilt-in isolation transformer
    Load power factor+1.0~1.0
    WiringInput: three-phase four-wire, output: three-phase four-wire/single-phase two-wire (automatically switch according to the output mode)
    Output parameters
    Number of output phasesThree-phase four-wire or single-phase two-wire
    Output modeThree-phase standard mode, three-phase unbalanced mode, parallel single-phase
    Output voltage0.0~ 300.0V(L-N)
    Voltage setting accuracyAccuracy: ≤0.5% Resolution: 0.1V
    Three-phase standard mode, three-phase unbalanced mode
    Rated current22.7A45.4A68.1A90.9A136.3A181.8A227.2A272.7A363.6A
    Parallel single-phase mode
    Rated current68.1A136.3A204.5A272.7A409.1A545.4A681.8A818.1A1090.9A
    Output frequency45.00~ 65.00Hz
    Frequency setting accuracyAccuracy: 0.02% Resolution: 0.01Hz
    Frequency stability≤0.02%
    Voltage distortion (VTHD)<1% (Linear load)
    Reaction time<2ms
    Voltage sudden change response time<20ms
    Three-phase angle120° ± 2° (Three-phase standard mode)
    Crest factor1.41±0.1 (sine wave mode)
    Source voltage effect load effect≤1%
    Efficient> 85%
    Measurement display
    Display mode8-inch color touch screen
    Voltage measurement accuracyAccuracy: 0.2%FS+0.2% display value Resolution: 0.1V
    Frequency measurement accuracyAccuracy: 0.02% Resolution: 0.01Hz
    Current measurement accuracyAccuracy: 0.3%FS+0.3% Display value resolution: 01A/1A
    Power measurement accuracyAccuracy: 0.5%FS+0.5% Display value resolution: 0.1kW/0.01kW/0.001kW

    Quality Vehicle Electrical Safety Testing Equipment Feedback Power Grid Simulator RS485 for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Sinuo Testing Equipment Co. , Limited
    *Subject:
    *Message:
    Characters Remaining: (0/3000)