Sign In | Join Free | My burrillandco.com
Home > Temperature Humidity Test Chamber >

Environmental Testing Temperature And Humidity Chamber 1000L IEC60068-2-78

Sinuo Testing Equipment Co. , Limited
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap Environmental Testing Temperature And Humidity Chamber 1000L IEC60068-2-78 from wholesalers
     
    Buy cheap Environmental Testing Temperature And Humidity Chamber 1000L IEC60068-2-78 from wholesalers
    • Buy cheap Environmental Testing Temperature And Humidity Chamber 1000L IEC60068-2-78 from wholesalers
    • Buy cheap Environmental Testing Temperature And Humidity Chamber 1000L IEC60068-2-78 from wholesalers
    • Buy cheap Environmental Testing Temperature And Humidity Chamber 1000L IEC60068-2-78 from wholesalers
    • Buy cheap Environmental Testing Temperature And Humidity Chamber 1000L IEC60068-2-78 from wholesalers
    • Buy cheap Environmental Testing Temperature And Humidity Chamber 1000L IEC60068-2-78 from wholesalers

    Environmental Testing Temperature And Humidity Chamber 1000L IEC60068-2-78

    Ask Lasest Price
    Brand Name : Sinuo
    Model Number : SN881-1000L
    Certification : Calibration Certificate (Cost Additional)
    Price : Customized
    Payment Terms : T/T
    Supply Ability : 1 sets/month
    Delivery Time : 45 days
    • Product Details
    • Company Profile

    Environmental Testing Temperature And Humidity Chamber 1000L IEC60068-2-78


    Environmental Testing Temperature and Humidity Chamber 1000L IEC60068-2-78


    Complied Standards & Clauses



    IEC60068-2-1:2007 “Environmental Testing-Part 2-1: Tests-Test A: Cold, IDT”

    IEC60068-2-2:2007 “Environmental Testing-Part 2-1: Tests- Test B-Dry heat, IDT”

    IEC60068-2-30:2005 “Environmental Testing-Part 2-30: Tests-Test Db: Damp heat, cyclic (12h+12h cycle), IDT”

    IEC60068-2-78:2012 “Environmental Testing-Part 2-78: Tests-Test Cab: Damp heat, steady state, IDT”


    Equipment Overview



    This test chamber is used for cold, heat, humidity, and dryness testing of raw materials and devices such as electronics, electricians, electrical appliances, plastics, etc. The purpose is to confirm the product's reliability of storage and transportation under high and low temperatures alternating heat and humidity.


    Technical Parameters



    Technical Parameters
    Control & OperationPLC and touch screen intelligent control system

    Chamber Size


    Inner SizeExternal Size
    1000*1000*1000 mm1280*2150*2050 mm
    Temperature Range-70 °C ~+150°C
    Humidity Range20%~98%RH
    Temperature fluctuation±0.5℃
    Humidity fluctuation≤2.5%
    Temperature deviation≤±2.0℃
    Humidity Deviation≤±3%
    Heating Rate≧2-3°C/min
    Cooling Rate≧1°C/min, average no load
    Load conditionNone
    Working noise

    A sound level≤70dB(A)

    (Measured in a soundproof room with an ambient temperature of 25°C and low echo. Using A weighting, test the average of 9 points. Each test point is 1 meter away from the noise source horizontally and 1 meter above the ground.)

    c) Controller specifications

    Technical indicators:

    1. 7-inch color touch screen

    2. Two control modes: program/fixed value

    3. Sensor type: two PT100 inputs (electronic sensor input optional)

    4. Output mode: voltage pulse (SSR)/control output: 2 (temperature/humidity)/2 4-20mA analog output/16 relay outputs (passive)

    5. Control signal: 8 IS control signals/8 T control signals/4 AL control signals

    6. Alarm signal: 16 DI external obstacle alarms

    7. Temperature measurement range: -90.00℃--200.00℃, (optional -90.00℃--300.00℃) error ±0.2℃

    8. Humidity measurement range: 1.0%--100%RH, error ±1%RH

    9. Communication interface: (RS232/RS485, maximum communication distance 1.2km [optical fiber up to 30km])

    10. Interface language type: Chinese/English

    11. Equipped with English input function

    12. Can be used with a printer (USB function optional)

    13. A variety of signal combination relay outputs, and the signals can be subjected to logical operations (NOT, AND, OR, NOR, XOR), referred to as PLC programming ability

    14. Diversified relay control methods: parameter->relay mode, relay->parameter mode, logic combination mode, composite signal mode

    15. Program editing: 120 groups of programs can be programmed, and each group of programs can program up to 100 segments


    Cooling system
    Operation modeAir-cooled mechanical compression single-stage refrigeration mode
    Heating and cooling devices

    1. Hitachi or Emerson low-temperature and low-noise scroll compressor (air-cooled heat dissipation method).

    2. Cooling method: air cooling

    Heat and cold exchange deviceSingle-stage refrigeration system, Emerson low-temperature and low-noise scroll compressor imported from the United States. Adopting ultra-high-efficiency SWEP cold coal heat and cold exchange design [made in Sweden (sus#316)], it is more efficient than the traditional internal spiral type.
    Heating load adjustment

    1. The automatic adjustment of the cold coal flow rate device is adopted to effectively take away the heating load of the product to be tested, which is synchronized with German/Japanese technology.

    2. Compared with traditional designs, the control stability and reproducibility are higher, and it achieves ultra-high performance in terms of power saving and energy saving.

    Refrigeration compressor

    Hitachi or Emerson low temperature and low noise scroll compressor


    Details

    Environmental Testing Temperature And Humidity Chamber 1000L IEC60068-2-78Environmental Testing Temperature And Humidity Chamber 1000L IEC60068-2-78


    Quality Environmental Testing Temperature And Humidity Chamber 1000L IEC60068-2-78 for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Sinuo Testing Equipment Co. , Limited
    *Subject:
    *Message:
    Characters Remaining: (0/3000)